Polarization analyzer is an instrument for polarization measurement and stability monitoring. It provides comprehensive functions to analyze the polarization characteristics of optical signals, and is used for real-time detection of beam polarization parameters, high-speed analysis and monitoring of polarization states. The polarization extinction ratio of narrow band light can be measured by combining the polarization state heat cycle heater with the measurement technology of heated fiber. Four Stokes parameters are obtained simultaneously using four channels, and the instantaneous polarization state (SOP) and degree of polarization (DOP) of the input beam are measured. Due to sampling:

With rates up to 1MS/s, the instrument is ideal for analyzing interference and fluctuating signals, as well as control applications that require real-time feedback of polarization information, such as digital control loops in automated manufacturing test systems. Using the upper computer software can be displayed in real time

The Bunga sphere, the trajectory of the upper polarization state, or the change of the polarization state over time in the form of an oscilloscope, can display the polarization state (PER) in real time on the Bunga Sphere window. For specific wavelengths and temperatures, it can be quickly calibrated with a built-in self-calibration program to optimize DOP and SOP measurement accuracy.

Features

1. Real-time detection of beam polarization state parameters

2. Can detect four Stokes parameters, polarization extinction ratio (PER), Degree of Polarization (DOP), ellipsometry, State of Polarization (SOP)

3.. Host computer real-time display

4.Poincare polarization state and parameters

5. Sampling rate up to 1M Samples/s

Application

1.SOP/DOP analysis and monitoring

2.PMD monitoring and compensation

3. Polarization state measurement and stability monitoring

4. Monitoring and measurement of fiber signal-to-noise ratio

5. High-speed interference

6. Automatic polarization extinction ratio PER test

7. Optical fiber sensing

Model

FF-8611

Wavelength range

1480-1620nm

SOP accuracy

0.25°

DOP accuracy

2%

PER measuring range

0-40dB

PER resolution

0.1dB

Return loss

APC:55dB,PC:45dB

Insertion loss

1.5dB Max

PDL

0.3dB

Input optical power range

-40~+10dB

Sampling rate

10k

Chassis size

235*104*300 mm